Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

7th May 1927, Page: 323, Column: 1

Firedamp Detectors*

By Colin McLuckie, Dip.R.T.C, M.I.Min.E.

Since it is impossible in one paper to give details of the countless number of indicators that have been invented since 1742, I propose to confine my remarks to the principles underlying the action of the various CH4 indicators, with a brief description of a few of the appliances, and incidentally to outline their respective merits and possibilities. Before proceeding to discuss indicators, however, it may be desirable to briefly outline the characteristics of firedamp.

The term firedamp is used to designate the inflammable gas mixture that is given off naturally from the strata. Firedamp may issue quietly from coal and its associated strata ; or it may escape under pressure from "breaks," making a noise like escaping steam generally referred to as a "blower" ; and sometimes it is released in large quantities under pressure and dislodges coal, and in some cases the roof and floor material. The latter phenomenon is termed an "outburst."

During the working of a particular coal seam that yields firedamp, the quantity of "gas" that will be liberated will be influenced by (1) the rate of advance of the coal face ; (2) the length of the face exposed ; (3) the presence of faults, dykes, and other geological disturbances ; (4) the proximity of other coal seams ; (5) the amount and nature of the subsidence produced during the mining of the seam ; (6) variations in atmospheric pressure.

The percentage of CH4 in the mine air is also influenced by the above factors. The former, however, is also governed to a large extent by the quantity of air circulated and the care exercised in its distribution.

Firedamp is a mixture of gases and consists chiefly of methane with traces of nitrogen, carbon dioxide, and in some cases other hydrocarbons and sulphuretted hydrogen. The presence of sulphuretted hydrogen and some of the hydrocarbons will give firedamp an odour, which will enable the gas to be detected by the sense of smell. Under certain circumstances, however, firedamp is odourless, so the nose cannot be relied upon as an indicator. The firedamp given off in the British mines very seldom contains any inflammable gas other than methane.

The composition of the firedamp used for experimental purposes in the mining laboratory of the Wigan and District Mining and Technical College consists of 98 per cent. methane, 1.4 per cent. nitrogen, and 0.6 per cent. carbon dioxide. Methane is the chief constituent in firedamp and its characteristics may be summarised as follows :—

Physical Properties of Methane (CH4). — It is colourless, tasteless, odourless, slightly soluble in water, has a specific gravity 0.56, thermal conductivity 0.000065, and the rate of diffusion compared with air is 100 : 75.

Physiological Properties. — Methane is non-poisonous. Its presence in the mine atmosphere diminishes the oxygen content. Ten per cent. of CH4 in air will diminish the oxygen content by approximately two per cent.

Chemical Properties. — CH4 is combustible. It will combine with the oxygen of the air when raised to the ignition temperature of approximately 700° C. The following is the combustion equation for methane in oxygen :—

From the combustion equation it will be seen that the carbon dioxide produced is equal to the CH4 consumed, and the steam generated is equal to twice the volume of the CH4 burned. The steam condenses and produces a reduction in volume equal to twice the volume of CH4 consumed. This reduction in volume is made use of in gas analysis in order to determine the amount of methane in a gas sample. Also some CH4 indicators are constructed to measure either the change in volume or the change in pressure produced when methane is burned in the region of a glowing platinum wire.

Limits of Inflammability of CH4. — Methane, like other combustible gases and vapours, is capable of exploding between well-defined limits. The latter are generally termed the "Lower and Higher Limits of Inflammation." The limits for methane are approximately — lower limit, 6 per cent. ; higher limit, 13 per cent.

Owing to the inflammable and dangerous nature of explosive mixtures of methane and air, and mixtures of air, coal dust and methane, it is necessary that colliery officials responsible for the ventilation should be capable of detecting and estimating the percentage of methane in mine air.

In the Coal Mines Act it states that "an intake airway shall not be deemed to be normally kept free from inflammable gas if the average percentage of inflammable gas found in six samples of air taken by an inspector in the air-current in that airway at intervals of not less than a fortnight exceeds one-quarter.

"No lamp or light other than a locked safety-lamp shall be allowed or used —

"in any seam, where the air-current in the return airway from any ventilating district in the seam is found normally to contain more than one-half per cent. of inflammable gas.

"Where the air-current in the main return airway is found normally to contain more than one-half per cent. of inflammable gas, that airway shall not be used for the haulage of coal.

"If at any time in any place in the mine the percentage of inflammable gas in the general body of air in that place is found to exceed one-and-a-quarter, the electric current shall at once be cut off.

"In a safety-lamp mine, a place shall be deemed to be dangerous if the percentage of inflammable gas in the general body of the air is found to be two-and-a-half or upwards, and in a mine worked with naked lights one-and-one-quarter or upwards."

It will be seen from extracts quoted, that it is necessary to detect as low as one-quarter per cent. of inflammable gas in the mine atmosphere.

* From a paper read before the Past and Present Mining Students' Association at the Wigan Mining and Technical College. Mr. McLuckie is Lecturer in the Mining Laboratory at the Wigan College.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
McLuckie, Colin    Lecturer  



Related Articles

Pub.
Date
Article (Newspaper)
07 May 1927  Firedamp Detectors* (The Science and Art of Mining)
21 May 1927  Firedamp Detectors (The Science and Art of Mining)
08 Jun 1927  Firedamp Detectors* (The Science and Art of Mining)
18 Jun 1927  Firedamp Detectors* (The Science and Art of Mining)

 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print