Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

15th January 1927, Page: 202, Column: 2

The Lighting Of Mines Underground

The question of lighting of mines is passed in review in the report of the Secretary for Mines as follows :—

More light is, perhaps, the greatest single contribution that could be made to greater safety and improved health and efficiency in underground work. The enormous improvements in electric lighting, the revolution which the incandescent mantle has effected in gas lighting (and more recently in lighting by portable lamps burning paraffin and petrol), and the developments of acetylene lighting, have all made abundant and suitable illumination available in other industries, but they have, so far, proved inapplicable to the lighting of inbye workings underground — partly because of the inherent physical obstacles, and partly because of the difficulties in overcoming the risk of ignition of firedamp. While these difficulties can never be altogether overcome, a limited application to underground mining of all these improvements ought to be possible, and experimental work to this end is being done.

(a) Flame Safely-lamps. — The flame safety-lamps in use to-day are very different from most of those in use in 1913, when official tests were instituted in order to give effect to Section 33 of the Coal Mines Act. The requirement laid down in the test memorandum that every "lamp must be provided with double gauzes or with some other adequate arrangement serving the same purpose" rendered obsolete over 310,000 single-gauze lamps out of a total of 740,000 flame lamps then in use, and had important effects on lighting power.

In 1925, following research work by Dr. R. V. Wheeler for the Miners' Lamps Committee, a fresh impetus towards the improvement of the lighting power of the flame safety-lamp was given by the grant of permission for the use in double gauze lamps of 20 mesh (26 or 27 S.W.G.) steel gauzes in place of the 28 mesh (28 S.W.G.) gauze which had been exclusively used for safety-lamps in this country since Sir Humphry Davy's time. With most types of double-gauze lamps now in use, the lighting power is considerably improved — without detriment to safety and without altering the structure of the lamp — simply by introducing a pair of the more open-mesh gauzes. Experience in the pit has shown another advantage which lamps fitted with 20 mesh gauzes possess over lamps fitted with 28 mesh gauzes, viz., that the light is not so liable to be put out by jolting, &c, when the lamp is being carried or moved. Considerable progress has been made on these lines. Upwards of 70,000 out of a total of 400,000 double-gauze lamps have been converted from 28 to 20 mesh gauzes — most of them to the use of two 20 mesh gauzes — but a minority (in a commendable, but perhaps unnecessary spirit of caution) to the use of one 20 mesh and one 28 mesh gauze. Experiment has shown that there are certain types (though they represent only a small proportion) of the double gauze lamps which gain, in fact, very little in lighting power from the mere substitution of 20 mesh for 28 mesh gauzes. In respect of these types, naturally, there is no marked change over to the use of 20 mesh gauze ; but the types of lamp which gain substantially in candle-power are being changed over very rapidly.

The 20 mesh gauze has not at present been applied to combustion tube lamps. Under the conditions of approval of 20 mesh gauzes, a second gauze would have to be introduced into the combustion tube lamp. This would involve some alteration of design, and it would be premature to embark upon this until other equally important questions of the effect of design upon lighting power have been more fully investigated. This investigation forms part of the work which is now in progress for the Safety in Mines Research Board. It may be pointed out here, since there was at one time some misunderstanding on the point, that the use of 20 mesh gauzes of copper wire is not allowed because they are not sufficiently firm and rigid ; nor is this mesh permitted for the large gauzes 5 to 6 inches in height which are used in what are known as porch and roadway lamps.

Further research by Dr. Wheeler and Mr. Woodhead, for the Safety in Mines Research Board, has shown an alternative method of improving the lighting power of flame lamps. It consists, in brief, of accurate attention to details which have hitherto been deemed unimportant or dealt with in a rough and ready way. They are the proper proportioning of the gauzes; the choice of the most suitable blend of oil; the use of enclosed burners and a shaped wick ; and the thickness and texture of the wick. The accurate adjustment, by experiment, of these details of design effects a marked improvement in lighting power without resort to 20 mesh gauzes ; and, indeed, Dr. Wheeler and Mr. Woodhead come provisionally to the conclusion that the efficacy of the 20 mesh gauze in improving the lighting power of many of the types of lamps now in current use may lie in its power to compensate automatically for such defects in design, and that, used with a scientifically designed lamp, the 28 mesh gauze may prove to give as good a light as the 20 mesh.

The two researches are thus complementary: the first shows how to get the best out of the large majority of the lamps now in use without reconstructing them ; the second shows the lines on which improvements in the design of new lamps can be brought about and is also being continued by the Safety in Mines Research Board.

There have been developments also in the special mode of construction where the air feed is introduced below the wick and in the use of perforated metal plates and fine tubes of metal in substitution for gauze.

(b) The Electric Safely Lamp. — At the beginning of 1913 the electric lamp was still in its infancy, only about 11,000 were in use as compared with about 366,000 to-day. The electric lamp has improved greatly in trustworthiness and durability, but, surprising as it may seem, the 2 or 2.5 volt lamp, which is still used almost exclusively, shows very little improvement in lighting power over the early electric lamps, except that the decrease of light during the shift is less marked than it was 12 years ago.

The electric safety-lamp, as it was at the beginning of 1913, could hardly have secured and strengthened its position as rapidly as it has done without improvements in design, and in lamproom technique and organisation, to make it a more trustworthy source of light and reduce its cost of maintenance to a figure comparable with the cost of maintenance of the flame lamp. These have been the main objectives of the electric lamp makers on the one hand, and mine managements on the other, and they have met with much success. But concentration on reduction in maintenance costs, vitally necessary as it was, may have militated against improved lighting power.

Apart from some sacrifice in the "working life" of the battery of the bulb, the prospects, in the present state of knowledge, of getting any marked increase in the lighting power of the 2 or 2.5 volt lamp is not hopeful, except by using a battery of a higher current capacity and incurring the disadvantage of additional weight and bulk. But the limits of improvement in this way in the 2 and 2.5 volt lamps are rather narrow, for, even if the handicaps still inherent in an accumulator of higher current capacity be accepted, there would probably be difficulties in getting a single 2 or 2.5 volt bulb to make effective use of a current of much more than 1¼ amperes. A much more hopeful method of attack is to take advantage of the higher efficiency of 4 and 5 volt bulbs by making use of a 4 or 5 volt accumulator as the source of current. But here, again, there are difficulties to be overcome : the normally constructed 4 and 5 volt accumulator requires more space than the ordinary electric lamp provides for it, and crowding is to be avoided in an accumulator.

Improvement in the lighting power of the electric lamp has also been brought about by providing for the more effective distribution of the light by the use of permanent reflectors. This has involved the partial abandonment of the "all-round" light at one time considered essential in safety-lamps for general pit work ; but this sacrifice, made at first with some misgiving, has on the whole been justified by results. In addition to a wide variety of "bullseye" lamps, whose use is limited to officials and members of rescue brigades, there are two types of reflecting lamp in use for general pit work, viz., (i.) the cap lamp in which the bulb fitting is carried on the head and connected, by means of a flexible cable, to the accumulator carried on the waist belt, and (ii.) the so-called pillarless lamp in which the usual four pillars and their covering cap are removed and replaced by a pivoted bridle handle carrying an adjustable reflector. The former has the greater theoretical advantage in that the reflection of the light can be fully controlled and that the light is brought much nearer to the work than a hand lamp can be, and yet — moving always with the head — has most of the advantages of an all-round light. But, in practice, the cap lamp has not met with so much favour as the pillarless lamp except in Scotland, where the miners are used to carrying a lamp on the head. At the end of 1925 there were in use approximately 17,000 pillarless lamps and 8,000 cap lamps, as compared with 5,000 and 2,000 respectively, at the end of 1922.

Mr. A. M. Henshaw has made an ingenious suggestion for a lamp which is a compromise between the cap and the pillarless lamp. It consists, in effect, of the head piece of a cap lamp mounted on top of the battery case and moving on a ball and socket joint so that the light can be directed, at will. Pit trials with this lamp have given promising results.

The use of protecting glasses lightly tinted yellow or yellow-green was suggested to the Miners' Lamps Committee by Sir Josiah Court as a means of eliminating glare arising from the high intrinsic brilliance of the very small source of light in electric lamps. The suggestion has proved to be a valuable one. Nearly 20 per cent. of the protecting glasses supplied for use during 1925 were tinted glasses and at some mines the workmen greatly prefer "canary lamps," as they call them, to those with clear glasses. The light cut off by a lightly tinted glass is inappreciable. Frosted glasses serve a similar purpose, but they cut off a significant amount of light and only a few hundred are in use.

Work has also been done in adapting to the electric safety-lamp the use of glasses of the "holophane" type and a few hundred are in use. The glass is shaped so as to present to the light a system of lenses or prisms which by refraction give a dispersed image of the source — so eliminating glare — and in addition, alter the distribution of the light in such a way (for example) as to divert more or less horizontally light which, but for refraction, would be cast on the roof or floor or cut off altogether by the metal parts of the lamp. An important secondary advantage of all these special types of glasses is that they reduce considerably the density and sharpness of the objectionable shadows cast by the pillars protecting the glass. Owing to the higher candle-power of the 4 and 5 volt lamps the use of tinted, frosted, or holophane glasses in them, to mitigate glare, seems likely to prove desirable.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Court, Josiah, Sir      
Davy, Humphry, Sir      
Henshaw, Albert Mayon      Whos Who Page
Wheeler, Richard Vernon, Dr.    S.M.R.B.  Whos Who Page
Woodhead, D. W.    S.M.R.B.  


 

mail
Mail:
Webmaster
Back