1st January 1927, Page: 181, Column: 1 Electricity In MinesAt the December meeting of the Manchester Geological and Mining Society a paper was read by Mr. J. A. B. Horsley, H.M. Electrical Inspector of Mines, on "Electrical Installations in Mines." Opening with a short discussion of the relative risks of "open sparking" in cables at high pressure and at low medium pressure, the author passed on to point out the importance of providing adequately for the automatic control of the current in the various component parts of an installation if the risk of fire and of explosion is to be minimised. The B.E.S.A., definition of flame-proof enclosure of electrical apparatus was referred to and the reason for the deliberate limitation therein to normal operating conditions explained. The inter-relation between effective automatic protection and a high standard of insulation and proper disciplinary control of the protective devices was insisted upon. The influence upon continuity of service of a complete system of automatic protection coupled with systematic testing was suggested, and the doctrine of the "stitch-in-time" invoked in this connection. Attention was drawn to the advantage of a continuous instrumental record of insulation and three diagrams given to show methods of applying leakage indicators in cases where their use is often omitted. The difference between excessive current in the normal path, i.e., overloads, and current of any magnitude in an abnormal path, i.e., leakage currents, was pointed out, and the risk of fire or of open sparking when fault currents of quite moderate magnitude are sustained, explained. Following discussion of the limitation of the fuse as a protective device, the principle of the circuit-breaker as an instrument of precision for the control of electrical circuits was considered, first, for the prevention of overloads, and then with reference to the prevention of sustained leakage. It was also pointed out that the momentary rush of current in the event of a short-circuit, due to a complete breakdown of insulation, is independent of the setting of overload trips in the circuit and is determined solely by the size of the plant, whether dynamo or transformer, and by the resistance or impedance of the intervening cables and apparatus. Simple, as well as discriminating leakage protection was described and illustrated with reference to the protection of items of plant as well as for cables. Upon the question of flame-proof apparatus the Author said :— It is not within the scope of this paper to discuss the flame-proof design of apparatus as distinct from the automatic control of the system and the maintenance of a high standard of insulation as aids to minimising the risk of igniting gas, but it will not be out of place to refer to three essential conditions for safety in that respect. Firstly, the apparatus must be flame-proof, i.e., it must comprise "an enclosure which will withstand, without injury, any explosion that may occur in practice within it under the conditions of operation within the rating of the apparatus enclosed by it (and recognised overloads, if any, associated therewith), and will prevent the transmission of flame such as will ignite any inflammable mixture which may be present in the surrounding atmosphere." This phrasing is a quotation from the general definition of flame-proof enclosure for electrical apparatus which was formulated recently by the British Engineering Standards Association. It means that the apparatus must be safe for use within the limits of its rating, in presence of an explosive mixture of firedamp and air. Secondly, "the (automatic) protection of the circuit must be such as to ensure, as far as practicable, that the highest recognised overloads for the apparatus shall not be exceeded, having regard to the amount of destructive energy available at the apparatus calculated from the size of generating plant and the impedance of the circuit between it and the apparatus." This phrasing is, likewise, a quotation from a footnote to the definition already, referred to. It means that although the enclosure may be safe while the apparatus is operated normally, it may be destroyed or rendered unsafe if the apparatus should happen to be called upon to deal with current or power much in excess of that for which it was designed. Thirdly, the standard of maintenance, and of discipline, must be such as to ensure, in general, that the electrical equipment involved shall be kept as nearly as possible in perfect condition and, in particular, that there shall be no improper or ignorant interference with the essential parts of any flame-proof enclosure, nor with the adjustment of the automatic protective devices that are associated therewith. This condition is perhaps the most difficult of fulfilment, but it would be nothing less than criminal folly to install and use electricity in a place where firedamp is likely to occur in dangerous quantity unless those responsible for its introduction were prepared not only to procure the most suitable equipment, but to so organise the supervision of the plant as to ensure, as far as possible, that it should be maintained in its original integrity. This is not an electrical problem so much as one of management and it is in recognition of this, no doubt, that an explanation must be sought, in part, for the varying extent to which electrical power is used in-bye in the coal mines of the United Kingdom. This of course is not the whole explanation for the difference, because natural causes must determine to no small extent the admissibility of electricity in spite of all that can be done to control the atmospheric conditions by attention to the ventilating system of the mine. A table was submitted by Mr. Horsley showing the relative use made of electrical power throughout the coalfields of Great Britain. The percentages in 1924 of the total H.P. installed for various purposes underground were : Haulage, 23.18 ; pumping, 23.54; portable machinery, 6.22; miscellaneous, 1.78 — total underground, 54.72. On the surface the percentages were : Winding, 7.23 ; ventilation, 6.95 ; haulage, 4.60 ; washing and screening 7.60 ; miscellaneous, 18.90 — total above ground, 45.28. A second table showed that of the 275.302 million tons raised in 1924, the mineral out by electrical machines was 30.371 million tons and by compressed air machines 20.028, giving a combined total of 50.299 million tons, the proportion due to electricity being 60.2 per cent.
|
|||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||