24th April 1926, Page: 315, Column: 1 Electricity In MinesBy R. Nelson. From paper on "Electricity in Mines: a Short Survey," read on 8th April before the Institution of Electrical Engineers. Although the special adaptability of electricity for use in connection with mining was mentioned in a paper before the Institution of Mechanical Engineers as early as the year 1852, it was not until 1883 that the first electric motor was set to work below-ground in a British mine. This was at the Trafalgar Colliery, Drybrook, Gloucestershire, and the person responsible was the late Sir Francis Brain. Electrical and mining engineers had, however, still to do a good deal by way of educating each other, and themselves, before they evolved practical and satisfactory solutions of all the problems presented by the distribution and use of electricity under mining conditions. There is now more than 1½ million horse-power of electric motors in use in and about the mines of Great Britain, whilst it is doubtful whether there was as much as 10,000 horse-power in 1900. This indicates a greatly accelerated rate of growth during recent years, but the total is, in itself, a moderate one, having regard to the field for the further use of electricity that still exists on the surface and below-ground in mines. The first general question which arises in connection with the use of electricity in mines is the source from which the current is to be derived. Supply from an outside source, whether from a public supply or from a neighbouring privately-owned generating plant, has not, everywhere, commended itself to colliery owners. This is one of the points about which there still remains a very common difference of opinion between electrical and mining engineers. The following is, in the author's view, the conclusion of matter. In many cases the point at issue is regarded too narrowly, It is often determined mainly or solely by a comparison of actual or estimated generating costs with the cost at which power can be purchased, leaving more or less completely out of account the advantages, many of them considerable, which go with the purchase of current from an outside source. Assuming a fairly close degree of correspondence between the rival sets of figures, the question goes some way towards answering itself if its implications are thoroughly appreciated. The practical advantages which follow from the purchase of current from an outside source are very important. Amongst them are: (1) The ease and quickness with which new machinery can be introduced without the necessity of additional capital outlay on generating plant; (2) the greater reliability, in general. of the supply, because it is the exception rather than the rule to see adequate spare plant provided at a colliery; (3) the convenience of having current "on tap," so that power and light are available at all hours of the day and night, at week-ends and on holidays, without the necessity of employing at these odd times more than the minimum of labour, and (4) the saving of time, money and worry, arising from the fact that the hitherto constantly recurring power problem has been, once and for all, definitely and finally settled. It is of course very difficult to give each of these facilities a cash value, but each of them definitely assists production by enabling the management to reduce idle time, one of the important factors tending towards the present-day diminution of output per employee in British coal mines. The matter of output per employee touches at once upon the most important result which usually follows from an unlimited supply of power, namely the increased use of mechanical power. It is only by this means that the output per employee can be increased and the cost of coal lowered without affecting the daily wages of the workers. There is one other point. The adoption of electricity for winding purposes without heavy first cost, already possible in two or three of the coalfields, is gradually being made possible elsewhere by the largely increased size of the units of generating plant now being installed in the stations of public supply authorities. Partial electrification of a colliery, leaving out the winding engines and the larger steam engines such as the fan engine, involving only partial shutting down of the colliery boiler plant, sometimes gives a somewhat disappointing result. Many schemes which have been only moderately successful as partial electrifications, have been greatly improved by a complete changeover. The winding engines are usually the last item to be converted, and they are, of course, the largest steam users and the most wasteful of all colliery steam engines. For these reasons the author is of opinion that the future will show a growing tendency towards the purchase of power from an outside source. In support of this conclusion it may be pointed out that in the newly developed South Yorkshire and Nottingham shire coalfields the larger collieries are gradually being interconnected by a system of transmission mains, so as to cheapen the cost of power by enabling most of the power plants to be shut down at week-ends and on holidays and by utilising more completely the available reserves of surplus power and spare plant. The collieries are beginning to appreciate that there is, after all, some merit in co-operative working. That is a short step, but a definite step, in the right direction. The total amount of coal raised in Great Britain in 1924 was 267,061,027 tons, and the number of persons employed 1,213,724. The total number of coal mines at work in 1924 was 2,855, of which 1,629 were wholly or partly electrically equipped. It follows that 1,226 mines, probably most of them small mines, were still at the end of 1924 without any electrical equipment, The horse-power of motors installed in and about coal mines at the end of 1924 is given herewith: Surface, 671,036 horse-power; underground, 810,896 horse-power; total 1,481,932 horse-power. Taken over the last ten years the average rate of increase per annum of the horse-power of electric motors installed belowground has been 6.83 per cent. The actual percentage increase of the total number of motors installed below-ground at the end of 1924 over the total number installed below-ground at the end of 1915 is 73 per cent,
|
|||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||