27th February 1926, Page: 256, Column: 2
Steam Winding Equipment
Some particulars of the steam winding equipment recently
laid down by the Wigan Coal and Iron Company, Ltd., at their
Parsonage Pit, Leigh, were given by Mr. Henry Piling, M.I.Mech.E.,
at the February meeting of the Manchester Geological and Mining
Society. The plant includes : (1) Steam winding engine (650
shaft h.p.), on No. 1 pit, 645 yds.; (2) steam winding engine
(790 shaft h.p.), on No. 2 pit, 1,000 yds.; (3) fan engine, 600,000
cub. ft. min. at 7-in. w.g. = 660 air h.p.; (4) mixed-pressure
turbo-driven air compressor, 12,000 cub. ft. min. at 100lb. per
sq. in. 2,000 air h.p.; (5) two turbo mixed-pressure generators
(one being spare) for general electrical purposes, each 1,500 k.w.
(6) three steam accumulators for receiving the exhaust steam
from the winder, the fan engine and the stand-by vertical steam
air compressor; (7) twelve Lancashire boilers, 150lb. pressure,
with stokers, coal conveyors, super-heaters and economisers. The
winding engine for the No. 1 pit is of the horizontal type, with
Galloway-Pilling patent drop-piston valves for the steam inlet,
and double-ported piston valves with a quick-acting motion for
the exhaust. The engines are designed to be capable of dealing
with the following loads and conditions :— Cage, chains and detaching
book, 8 tons; coal, eight tubs at 10 cwts. each tub, 4 tons;
tubs, eight at 4 cwts. each, 1 ton 12 cwts. ; a locked-coil rope,
1¾ in. dia., at 45lb. per fathom; depth of shaft, 645 yds.; from
surface to the centre of the head gear pulley, 30 yds. ; total,
suspended rope, 675 yds. = 6 tons 15 cwts.; total load, 20 tons
7 cwts. ; winding time, 48 sec. ; steam pressure, 150lb. per sq.
in. max. to 120lb. min.; superhead, 200 deg. Fah. The engines
exhaust against a back pressure not exceeding 6 lb. above
atmosphere. In case of emergency these engines will have to
wind men from a depth of 1,000 yds. This will be done by fixing
a rope 350 yds. long together with a single-deck cage to the bottom
of the right-hand cage slings. The engines will then wind from
the 1,000-yd. level to the 650-yd. level, the men at that point
changing from the lower cage to the main cage, and being wound
thence to the surface. The total load in this case, when winding
men, will be 20 tons 13 cwts. To compensate for the extra unbalanced
load, suitably-designed balance weights will be attached
to the left-hand cage. The engines have 40-in. dia. cylinders
by 6 ft. stroke. The conical winding drum diameter varies from
16 ft. to 22 ft. Concluding, the author, referring to the task
of comparing proposals for direct-acting steam winders with
proposals for electric winders, remarked that, in view of the fact
that the capital expenditure for direct-acting steam plant or for
electric plant is approximately the same, the deduction is that
local conditions should be most cautiously considered in each
case, with special attention paid to the scattered or concentrated
nature of the plant. With scattered plant, the adoption of electric
driving confers certain advantages, but no single solution is
yet practicable.
 |
 |
|