13th February 1926, Page: 235, Column: 2
Borehole Surveying Instrument
The Institution of Mining and Metallurgy has had under discussion
a paper, published in the January Bulletin, by Dr. John S. Owens,
B.A., describing a new instrument for surveying boreholes.
To obtain the true direction of a borehole so that its course
may be plotted it is necessary to know the deviation from the
initial direction at each point in its depth. The instrument described
consists of an external water-tight casing, which protects
the internal mechanism from injury. The latter is arranged in
two carrier tubes connected mechanically and electrically by means
of a bayonet joint which permits them to be withdrawn as a whole
from the external casing for adjustment, setting and charging.
A clinometer and a magnetic needle, together with two electric
bulbs for illumination, are mounted in a cradle which is suspended
in one of the carrier tubes and is free to rotate on its long axis.
Both clinometer and compass bowl are free to rotate on axes
at right-angles to the cradle pivots; so that, irrespective of the
position of the external casing, the clinometer and magnetic needles
always swing in vertical and horizontal planes respectively. The
other carrier tube contains the mechanism which controls the
length and number of, as well as the interval between, consecutive
exposures. It consists of a clock-operated controller which makes
and breaks the circuit of electric lamps. The clinometer is an
eccentrically-weighted drum carrying a strip of sensitised paper
which oscillates close to a diaphragm in which the apertures
previously mentioned are cut. In the compass, the magnetic
needles and the apertures are mounted upon a spider, and this
moving element is encircled by a strip of sensitised paper carried
upon a drum fixed relative to the moving element. The needles
and record paper are enclosed in a bowl so that all light is excluded,
except that which passes through the recording apertures. The
top of this bowl is provided with an opal glass dome illuminated
by the lamps, so that the whole of the interior of the moving
element is flooded with a diffused light when the lamps are lighted;
thus the position of the magnetic needles is recorded on the paper
photographically. When the instrument is horizontal, each lamp
lights half of the opal dome, while if vertical, one lamp lights
the whole dome, thus keeping a constant illumination whatever
the position of the instrument.
 |
 |
|
Names mentioned in this article
|
 |
 |
| Name | Age | Occupation | Notes |
| Owens, John S., Dr. | | | |