Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

20th October 1855, Page: 3, Column: 2

The Late Boiler Explosion At Walker Iron Works

Adjourned Inquest

On Tuesday afternoon last, pursuant to adjournment from the 9th inst, the inquest on the bodies of the five men and two boys, who lost their lives in consequence of the boiler explosion which occurred in Walker Iron Works on Monday, the 8th instant, was resumed by the coroner, Stephen Reed, Esq., in the news-room of the Mechanics' Institute, at Walker. Mr. Matthias Dunn, C.E., Government Inspector of Mines, whose attendance had been procured by the coroner, in order that he might assist in the investigation, was present, and it will be seen materially assisted in eliciting evidence on important points bearing on the inquiry :—

William Livingstone, who had been examined on the previous occasion, was recalled. He said : I stated on the last occasion that I examined the valves of the boiler and found them all closed. Those valves, being the feed valves, would prevent any more water getting into the boiler. I stated also that the boiler was fed by warm water from a tank. One of the safety valves was blown away. The other remained ; I examined it. It was not fast. It was in good order. The boiler was about 6 feet 8 inches in diameter and 25 feet long. — By. Mr. Dunn: One continuous feed pipe supplies six boilers. There is a branch pipe and valve to each boiler. We have self-acting stop flaps inside each cylinder boiler. They are not come-at-able by any one from the outside. The stop-flaps are to prevent the water priming from one boiler into another. If any of these flaps was to get out of order the boilers might prime from one into the other. In that case, one boiler might be filled with water and cause a deficiency in the other. The flap is placed within four or six inches from the boiler bottom. If any sediment became deposited in the bottom of the boiler. It might prevent the flap from acting. The water of the Tyne does deposit a considerable sediment. One main steam-pipe also supplies all the boilers, and there is a branch pipe and valve to each. The boilers might prime through the steam-pipe, but I have never known it to be the case. I saw the floats at 7 in the morning, and saw that the index was in its proper position, but did not try the floats, though from the index I considered that the floats were right and that the supply of water was sufficient. If I found the boiler in a dangerous state from want of water, I would immediately dumper up the fires. In drawing the fire, it would for the time increase the intensity of the boat. I would also lift the safety valves as expeditiously as possible. I would not cool the boiler with water. In this boiler we could not ease the safety valve without standing over it, but when the fire was out there would be no danger. The safety valves are 4 inches in diameter. If the valves were larger the steam would be got off quicker. The steam pipe had a valve through which the steam escaped into the air. By shifting the weight near the fulcrum the steam would discharge itself. We have no lead plugs in our boilers. When the water was boiled down the lead would become fused. If there had been a lead plug on the side of the boiler where the fire passes round in the flues, when heated to a certain point, the lead would melt and the steam and water would flow to the fire and give warning where there was danger. It is common to have a plug of this kind in locomotive boilers. It would be applicable as a safe-guard to other boilers. If there is care used, the danger is not greater from so many boilers being fed from the same pipe. There was no apprehension on the part of any one before the explosion occurred.

Thomas Hall being sworn, said he lived in Hudson-street, Walker. I am an engineman, and had charge of the boiler which exploded on Monday the 8th of October inst. I came to work about half-past three on Monday morning. My first duty was to examine the boilers, but my father, who is above me, took that duty off my hands on that morning. The engine went on perfectly well till the explosion took place at half-past ten. About a quarter of an hour before, there appeared to me about four inches too much water in the boiler that exploded, and I therefore shut the feed and cut the water off. I did not open the feed-valve again. At this time the fire was slack. I suppose that the water in that boiler would scarcely decrease a ¼ of an inch by evaporation between the time that the water was cut off and the explosion. I do not consider there is any danger attending the getting up the steam after the engine has been off work. It is a matter of prudence to heat the boiler gradually, though we get up the fires as quick as we can. We cannot get them up very quick. I had examined the index four times before the explosion. I examined it first at half-past seven o'clock before the engine was stopped. Half an hour after, I did so again, at half-past eight I did so again, and the fourth time I examined it was a quarter Of an hour before the explosion. On all these times I considered the boiler to be in proper working order and quite safe. I cannot form an opinion of the cause of the explosion. By Mr. Dunn and the Coroner: I am 19 years of age. I have been an engineman about five years. I have had charge of the boilers at Walker about nine months. The boilers are six in number, all connected together. The boiler that exploded might prime, if the fire under it was stronger than that of its neighbour. She could not prime out of the feed pipe, because the flap inside the boiler is expected to be shut. She might prime in consequence of a heavy fire through the steam-pipe, the water branching into the adjoining boiler. We would have evidence of that in the engine. At the time of the explosion, there was no heavy firing. The stoker was cleaning the grate of the boiler when it exploded. To clean the grate, the fire is pushed to one side ; the scaurs are then raked from the vacant side, and the other side of the grate is then cleaned in a similar manner. A sharp man can clean a fire in twenty minutes. Before beginning to clean we diminish the fire. I am positive I saw the boiler all right a quarter of an hour before the explosion. My father left at seven o'clock. After that time the boiler was entirely in my charge. If I found a boiler in a dangerous state, I would immediately draw the fire; I would shut off the boiler from the other boilers, and then leave it to cool down, I would blow the steam off by opening the valves as soon as possible. I do not consider that in drawing the fire the heat would be intensified at the time. Considered it would be safer to draw out the fire than to damp it. There were two floats in each boiler. They sometimes go wrong by losing the inside weight off. I am not aware that there was any apprehension with regard to this boiler. It had undergone repairs a few months ago. I can't believe it was want of water that caused the explosion. I think the boiler would bear more pressure than the steam at that time was at. If the plates at the bottom of the boiler became overheated it would have a tendency to cause an explosion. The plates could not become overheated by firing, I think. If there was sufficient water. By the Coroner: We use the Tyne water. We clean the boilers once a fortnight. Sometimes there is a considerable sediment lodged at the bottom of the boiler, on which it forms a coating mass. If the boiler was much heated it would cause that coating to crack. In that case the water would fill between the coating and the boiler, and an explosion might be the consequence. The sediments was removed from the boiler on the Sunday, the day before the explosion.

The Coroner: That is a strange day to work, is it not ?

Witness : It is the only day there is to do it in.

The sediment becomes so compact and hard that a hammer has to be used to break it. Sometimes there is scarcely any sediment. — By Mr. Dunn : The flap within the boiler that exploded was between five and six inches from the bottom. In some boilers it was not more than between three and four. Never saw any of the flaps obstructed. There was never anything else but sediment in the water. Considered six boilers equally as safe working together as it would be to work one alone. I have seen a lead plug in a boiler. These plugs are difficult to work with in a high pressure boiler. The lead, plug on melting out would cause the fire to be extinguished. Considered it safe enough without a plug. It was a high pressure boiler that exploded. Had never seen lead plugs in high pressure boilers. Had seen it in a locomotive boiler, which was lightly pressed. His objection to the plug was the difficulty of preventing it from leaking. The same difficulty applied to railway locomotive engines in which such plugs were used and where the pressure was very great.

[The Coroner here explained to the witness a contrivance which a scientific gentleman had written to him about, and the object of which was to prevent accidents by boiler explosions. A diagram of the contrivance was given to Mr. Dove, engineer of the works, in order that it might be submitted to the firm for adoption, if approved.]

James O'Neil was sworn. He was, it appears, the stoker of the boiler adjoining that which exploded. His evidence was immaterial, except that he corroborated the statement of the engineman, whom he said he had seen examining the boiler about a quarter of an hour before the explosion.

Patrick Gribbon, stoker, living at Walker, stated that he went to work at six o'clock on the Sunday night before the explosion to put on the fires and get the steam up. He put the fires on at all the boilers, attending to that which exploded last. He left at six on Monday morning, when the steam was just getting up ready for working. The mill had not commenced when he came away.

The Coroner remarked that the man who attended to the fire of the boiler that exploded and the adjoining boiler being killed, they could not carry the evidence respecting the state the fire in the boiler that exploded any further.

William Short was then called. He said; I am a boiler smith. I live at Walker, and attended to the repair of the boilers at Walker Iron Works. The boiler which burst underwent a thorough repair about three years ago. A great quantity of new plates were put in. The boiler was capable of bearing a pressure of about 50lbs to the square inch. On the day before the explosion took place one of my men examined the boiler that exploded. He was inside the boiler. He found that there was a small crack about an inch long in the bottom of the boiler. He repaired the crack. The man's name is Alexander Campbell. After the explosion he pointed out to me the particular part of the boiler in which he made the small repair. There did not appear to me to be any deficiency in any part of the boiler. He had repaired the part by taking out the rivet and replacing it by another. There had been a small leakage at the place before the repair. Could assign no reason for the boiler exploding. I considered the boiler a very strong one. If there had been a sufficiency of water in the boiler, it could not have exploded from the heating of the plates. I examined the boiler after the explosion. I think it had been overheated ; it had the appearance of having been red-hot. The plates had a red and scorched-like appearance. By Mr. Dunn: I have seen lead plugs used in cylinder boilers such as that which burst. If a plug of that sort had been in the side of the boiler bottom it would have melted and the water blown through the plug-hole would have extinguished the fire underneath the boiler, and warned the men of the danger. I never saw a plug in a boiler of heavy pressure. I do not know why it should not be so. A plug of the kind mentioned would have tended to the safety of the men. The thin parts of the plate of the boiler as it now is are still sufficiently strong to sustain a pressure of 50lbs to the square inch. The top of the boiler is whole, but the bottom was rent asunder by the explosion. Both ends were blown out. I do not think it was the intensity of the steam, but want of water that caused the explosion. Six years ago a tube boiler exploded at the works. I cannot tell the cause.

The Coroner then stated that he could not finish the inquest that day, as Mr. Dunn's and the evidence of the engineer in chief of the works remained to be taken ; and as he had some inquests of a serious nature at Bellingham and elsewhere which would engage his time, he would not be at liberty until the 30th of this month. — The inquest was accordingly adjourned till October 30.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Campbell, Alexander    Boiler Smith  
Dove, —    Engineer  
Dunn, Matthias    H.M. Inspector of Mines  Whos Who Page
Gribbon, Patrick    Stoker  
Hall, Thomas    Engineman  
Livingstone, William      
O'Neil, James    Stoker  
Reed, Stephen    Coroner  Whos Who Page
Short, William    Boiler Smith  



Related Articles

Pub.
Date
Article (Newspaper)
20 Oct 1855  The Late Boiler Explosion At Walker Iron Works, Adjourned Inquest (Newcastle Guardian and Tyne Mercury)
03 Nov 1855  The Walker Inquest (Newcastle Guardian and Tyne Mercury)
17 Nov 1855  The Late Boiler Explosion At Walker, Close Of The Inquest (Newcastle Guardian and Tyne Mercury)

 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print