An explosion of firedamp occurred on 15th July at South Medomsley Colliery, Durham, A quantity of firedamp was ignited by the flame of a hewer's candle at the face of a stepped longwall gateway in the Tilley Seam. The flame traversed a face airway to an adjoining gate which had stopped at a fault outbye, along this roadway and through a flat on the main heading. The hewer was uninjured but a driver standing in the flat was severely burnt and died later. It is probable that the flame was slightly propagated by coal dust from the face. Firedamp had not been seen in the seam for the past 20 years, and none was detected after the ignition. Breakers were discovered in the floor near the site of the explosion and it is probable that gas came from the seam below. The seam was abandoned following the ignition.
|
|||||||||||||||||||||||||||||
![]() |
||||||||
|