This man was hewing in a headways 10 feet wide in a seam 5 feet 3 inches thick; the roof of the place was a stone band covered by a top coal which was not worked; the maximum timbering distance was 6 feet; the nearest pair of gears to the face was 4 feet from the coal before the hewers started kirving; they kirved under the band for a distance of 3 feet without putting in any more roof supports; the band forming the roof was thinner at this place than usual, being only about 7 inches, and while the deceased was sitting waiting for the putter a large flag of stone fell; it canted out the last pair of gears under which deceased was sitting and fell on to him, inflicting such injuries that he died almost immediately; the timbering rule was not carried out; if it had been the accident would probably not have happened
|
|||||||||||||||||||||||||||||||||
![]() |
||||||||
|