On November 28th an accident occurred at the Pelton Colliery which caused the death of a fitter. Some alterations were being made in the Blacksmith's shop, and the deceased was carrying a portable Electric Lamp intending to give light to a man who was up a ladder attending to a pulley. The ordinary working pressure was 120 volts and the lamp was attached to a flexible cable to enable it to be moved to any required position in the shop. The deceased shouted and fell down, and it was subsequently found, on a post-mortem examination being made, that there was a charred patch about the size of a shilling on the top of the scalp, and two blisters on the palm of the left hand. Other post-mortem indications led to the belief that death had occurred through electric shock. The ground on which the man was standing was damp. Shortly after the accident the lamp was tested by the colliery electrician and nothing wrong was found with it, and again a few hours later by an expert who came out from Newcastle for the purpose, with the same result, and again later in my presence. The cable was also tested. The outside glass globe and brass protection cage had been removed in order to get a better light, but this would not affect the lamp itself. The following is an extract from a report by Mr. Grouves, the electrician from Newcastle, which was read at the Coroner's enquiry "The first thing I did was to examine the lamp in question, and from this I found no trace of a fault of any description, the lamp and its connections being in perfect condition. I next questioned the electrician of the Colliery who, I understood had carried out some tests on the lamp, and found from his statement, that he had subjected the lamp to such tests as should have detected the fault if one had existed. The pressure he applied was 440 volts, whereas the lamp is only required for use at a pressure of 110 to 120 volts. "I then had the lamp connected to the circuit, which was pointed out to me as one to which the lamp was connected at the time the man met his death. I also asked Mr. Thompson to arrange the cables and place the lamp, so that the conditions should be as nearly as possible identical with those existing at the time of the accident. This was done, and I then had the pressure applied to the lamp, which immediately lighted up. The lamp was then handled for several minutes but no sign of a shock was apparent. "The fact that the glass globe and brass protection cage were removed from the lamp, could not have been the cause of any shock, as these are only required to protect the lamp from mechanical injury. "I was also informed that immediately the deceased fell, the lamp went out, although the pressure was still on. I therefore made a further examination for the purpose of ascertaining the cause of the light failing and found that it was simply due to the lamp being loose in its socket, so that a sudden jar applied would cause the lamp to come away or jump from its connection. This however, could have no other effect than cutting off the light. "I have come to the conclusion, therefore, that there is nothing, so far as can be seen, to show that it was possible to obtain a shock from the lamp, and the fact that the deceased walked some distance with the lamp, before falling, proves conclusively that there could not have been a fault on the lamp when he first handled it." The most probable explanation is that when held in a certain position the electric wires came in contact with the brass fittings of the lamp so that the part which the man was holding became alive and gave him the fatal shock.
|
|||||||||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 31 Dec 2022
|
Search |
|
|||