On 25th October, a boiler explosion took place at Scremerston Colliery, near Berwick-on-Tweed, causing the death of the stoker, with imminent risk to many other persons around. The winding engine had three cylindrical boilers working at high pressure, (40 lb. per inch,) one of which unexpectedly exploded on the 21st instant, but without injuring any person, and on the 25th one of the pumping engine boilers, (also one of three) but working at low pressure, also exploded, killing the stoker, and rending the boiler into three parts. The boiler was 8 feet diameter, and 30 feet in length, the original thickness of plate had been 5/16ths of an inch, but had worn 16 years, so that around the flues portions of the plate were reduced to 3/16ths of an inch. Then with regard to the pressure, it was understood by all parties to be only 8 or 9 lbs. per inch; but upon weighing the ball and calculating the area of the safety valve in conjunction with the respective proportions of the lever, the pressure was ascertained to be nearly double the expected pressure, which, with the diminished thickness of the plate and the large dimensions of boiler, led to the conclusion that it was owing more to the actual weakness, than to any neglect or oversight of the man in charge, for there was convincing evidence that very shortly before the explosion, the boiler to all appearance was well furnished with water. In regard to boiler explosions and their preventives, I may remark that the ordinary application in this district is a steam safety valve and ordinary wheel float, viz. :— A stone or iron weight within the boiler, counterbalanced by a ball outside, the whole working over a pulley attached to the boiler, the apparatus shewing the rise and fall of the water ; and since the amended Act I have constantly urged that each of these applications should be duplicated either by one apparatus or another, but very few common boilers are furnished with glass tubes, or gauge cocks, although steam indicators have in many cases been introduced. In tube boilers, of which description very few exist in my district, the ordinary float is greatly inapplicable, in which case gauge cocks and glass tubes are adverted to, but neither one nor the other are to be trusted singly.
|
|||||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 31 Dec 2022
|
Search |
|
|||