John Phelan
Two persons were killed and one severely injured on a longwall working at Dawdon Colliery, Durham, by a large fall of roof. The seam overlain by a hard post roof, and consisting of 3ft. 2ins. of top coal, 16ins. of band, and 7ins. of bottom coal, had been worked by the bord and pillar method, but longwall gateways with stepped faces were being opened out in the top section owing to the thickening of the band and deterioration of the bottom coal. Two gateways 13 yards centres, had been driven 50 and 40 yards respectively from the winning headways, the band being taken up in the gateways to make height and to furnish material for roadside packs. Wood props and headtrees with very occasional planks were used to support the roof. Two fillers, a coal cutter man, a "cleaner-out," and a putter were at the face when a sudden roof weighting — the first since the district commenced about one month previously — occurred and the roof collapsed over almost the whole length of face worked by the two gateways. One filler and the cleaner-out were buried and instantly killed and the putter was found to be severely injured when released about 10 hours later with the other two men who, fortunately, were uninjured, as the small portion of the roof at the right side of the face where they were working had not fallen. In my view the accident was brought about as follows. The packs were not substantially built. The roof was strong and had not fallen in the waste between the gateways but had settled and had thrown weight on the face. When the first heavy weighting occurred, the packs allowed the roof backbye to subside still further and this threw nearly all the weight on the face. The line of coal face was the only rigid support and the roof fractured along this line. The face supports were unable to hold it and the whole stretch of face collapsed. Apart from the actual method adopted of opening out the district, namely, the stepped face system of longwall, with which I do not agree because it does not lend itself to systematic roof control, I should like to call attention to the following points: 1. Strong roofs have a tendency to hang for a while and then weight suddenly. This should be anticipated and special precautions should be taken to guard against accident when the weight does come on. 2. Much depends on the nature of the packs not only for support but for inducing the roof to break in the wastes. Substantial pack walls are essential. 3. In any new district, until the roof has been more or less got under control the packs, which should be built up as close to the face as possible, and face supports, should be stronger than those intended for normal working.
If you are researching John Phelan (e.g. for family tree purposes) and you would like to hear from others with the same interest then please complete the details in the following form. We will show the information you provide on this page so that you can be contacted.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 31 Dec 2022
|
Search |
|
|||