logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Master Name Index
What's new in the site
Donate to support the Museum
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious

  Individual Details   Individual Details  
 


William Jones

Age:   43
Died:   18th Aug 1924
Accident:   18th Aug 1924 2.30 a.m., 4th hour of shift
Year Born:   abt. 1881
Colliery:   Gwaunclawdd
Company:   Gwaunclawdd Colliery Co., Ltd.
Occupation:   Haulier (night)
Notes:  
Buried:   [not known]
Category:   Explosions of Firedamp or Coal Dust :: Miscellaneous

Description

Fatal Explosions.

An explosion took place at Gwaunclawdd Colliery, Breconshire, on 18th August, 1924, at 2.30 a.m., whereby E. R. Kinnard, a fireman, and W. Jones, a haulier, were burned. About four hours later, a fireman, named Gethin, ventured into the area affected by the explosion, and was rendered unconscious by the afterdamp. Happily, he was got out, and he soon recovered, but his action in going into the district as he did was foolhardy in the extreme, putting not only his own life into danger but also the lives of others who had to rescue him.

It had been the custom at this colliery to stop the ventilating fan after the men were all out of the mine on Saturdays until the following morning. On Sunday, 17th August, the fan was restarted at 8.30 a.m., and Wm. Griffiths, an overman, going into the pit to inspect the workings and to work the pumps, found that gas had collected in the Dip District of the Bluers Seam, and he reported its presence.

An electrically driven pump stood in the return airway from the district, as shown in Plate No. 1. Griffiths short circuited the air, so as not to move the gas, and had the pump worked for two hours — from 1 p.m. to 3 p.m. — when he left the pit. Before doing so he closed a door he had had kept open during the time the pump was at work, expecting that the air current, taking its normal course, would clear the gas.

At 11 p.m. the same evening, Edward Richard Kinnard, a fireman, who had received a note from Griffiths telling him that there was gas in David Evans' Heading and Wat Stone's Heading, went into the pit with William Jones, a haulier, to work the pumps, and to do anything necessary to enable the pit to work next day.

At 2.30 a.m. they arrived at the pump in the Dip District, and Kinnard started it. He then went towards the face by the intake airway (not used for the haulage of coal), and found gas as Griffiths had reported. Discovering some brattice sheets disarranged, he put them right, with Jones' help, and in about half an hour found the body of gas was being moved by the air current and going towards the pump. Presently an explosion took place, which burned and knocked down both men and put out their lights. They managed to get outbye in the dark, Kinnard stopping the pump motor as he passed. He went to the surface alone, and, returning with a light and assistance, found Jones about half way up the drift. Jones walked straight home, but had later to be taken to the Swansea Hospital, where he died on the 27th August from his injuries.

The construction of the motor driving the pump was not such as to comply with General Regulation 132 (ii), in that its commutator was not so enclosed as to prevent open sparking, with the result that the firedamp which had been set in motion outbye, consequent upon the repairs to the brattice sheets, became ignited.

Serious as were the results of this explosion, they might easily have been much more so. The stoppage of a ventilating fan is not at any time a light matter, and even when it must be stopped in case of accident, careful handling of the resulting conditions is called for. In this instance the fan ought not to have been stopped at all, and when the district was found in consequence of its stoppage to have become fouled with an accumulation of gas, the manager should have been informed and should have given the removal of the gas his personal attention.

Care should be taken when buying electrical apparatus for use in parts of mines where inflammable gas is liable to occur to specify clearly that it must be of flame-proof construction and otherwise in compliance with the Regulations.

By your direction, proceedings were instituted against the owners, alleging three breaches of the Mines Act or General Regulations, and against the manager, alleging nine breaches.

The charges against the owners were dismissed. The manager was fined £23 and ordered to pay £11 2.s. in costs. For statistical purposes — the case having been heard during 1925 — details of the informations laid and of the verdict will be given in Section IV of my next report.


Sources
  • 1924 Mines Inspectors Report, Swansea Division (No. 7) by W. J. Charlton, H.M. Inspector of Mines [DMM Ref: L-01624 - Tom Bainbridge Collection], Page: 44, Accident Number: 2
  • 1924 Mines Inspectors Report, Swansea Division (No. 7) by W. J. Charlton, H.M. Inspector of Mines [DMM Ref: L-01624 - Tom Bainbridge Collection], Page: 9

Researchers

If you are researching William Jones (e.g. for family tree purposes) and you would like to hear from others with the same interest then please complete the details in the following form. We will show the information you provide on this page so that you can be contacted.

What is your name?
What is your contact email address?
What is your research interest?

 

Return Return   Return Return to Top

 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 15 Mar 2023

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print