|
John Martin
By Electricity. Five persons were killed by the same number of accidents due to electric shock. I give below a more detailed description of them than appears in Appendix I, as they suggest means which should be taken to prevent similar accidents in future. I was not in charge of the district when the first four of these accidents occurred, and I, therefore, give below a summary of the reports made by Mr. Nelson, His Majesty's Electrical Inspector of Mines, on them. The fourth occurred at Auchengeich Colliery, belonging to Messrs. James Nimmo & Co., Ltd., on May 12th.The deceased was in charge of the running of a face-conveyor, and he was actually about to switch off current from the conveyor motor at the time of the accident. Current at this colliery is generated as three-phase current at 440 volts. It is used at this pressure chiefly for pumping and for driving coal conveyors. Armoured cables are used. At the gate-end switch, controlling the conveyor motor south of the shaft in the Coking Coal Seam, there was, at the time of the accident, a short length of armoured cable connecting up a 400 volt-100 volt transformer, current at the lower pressure being used for lighting. The deceased was heard to groan when in the act of switching off the gate-end switch, and he was then seen to have his left hand on the lighting transformer. An effort was made to pull him off, but it was not for some few minutes afterwards that he was freed by the switching off of the current at a switch in series with the gate-end switch some 20 or 30 yards away. An effort was made to restore deceased, but it was unavailing. Examination of the lighting transformer showed that the cable inside the case had become bared, and there is no doubt that contact between this bared part and tbe transformer case was the primary cause of the accident. In the ordinary way the transformer case would be connected to earth through the armouring of the incoming cables, but this connection (through a brass gland) must have been a very poor one at the best, and it had failed. It is probable that deceased placed his hand on the transformer cable in approaching the gate-end switch, and that in so doing he made contact between the bared cable and the transformer case and caused the armouring, which had been very poorly secured, to slip out of the brass leading-in gland. In this way the transformer case would be made "live." Deceased was standing on a wet iron plate at the time of the accident, and it is probably due to this fact that the 240-volt shock he received proved fatal. The neutral point of the generator was connected to earth. This case indicates the uncertainty of depending upon a gland for an earth connection. It is better not to depend only upon a gland, but to connect in addition a short length of cable to the armouring of the incoming cable and to the body of the transformer by properly designed lug connections. No stress can possibly in these circumstances be taken by the earth connections, and this is as it should be. The earth circuit is frequently regarded as of no great importance, certainly of less importance, than the main circuit. It is not, however, of less but of greater importance, for if the latter fails it merely means the shutting down of the machine, whereas if the former fails it may result in a fatal accident. The transformer gland was evidently not designed for the purpose for which it was used, namely as an earth connection to the cable armouring. It was probably intended merely as an oil-tight gland for the cable.
If you are researching John Martin (e.g. for family tree purposes) and you would like to hear from others with the same interest then please complete the details in the following form. We will show the information you provide on this page so that you can be contacted.
|
|||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 31 Dec 2022
|
Search |
|
|||