logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Master Name Index
What's new in the site
Donate to support the Museum
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious

  Individual Details   Individual Details  
 


John Martin

Age:   16
Died:   12th May 1910
Accident:   12th May 1910
Year Born:   abt. 1894
Colliery:   Auchengeich, No. 2
Company:   James Nimmo and Co., Ltd.
Occupation:   Drawer
Notes:  
When switching on electric current at a face conveyor he was electrocuted
Buried:   [not known]
Category:   Miscellaneous Underground Accidents :: Haulage :: By Electricity

Description

By Electricity.

Five persons were killed by the same number of accidents due to electric shock. I give below a more detailed description of them than appears in Appendix I, as they suggest means which should be taken to prevent similar accidents in future.

I was not in charge of the district when the first four of these accidents occurred, and I, therefore, give below a summary of the reports made by Mr. Nelson, His Majesty's Electrical Inspector of Mines, on them.

The fourth occurred at Auchengeich Colliery, belonging to Messrs. James Nimmo & Co., Ltd., on May 12th.

The deceased was in charge of the running of a face-conveyor, and he was actually about to switch off current from the conveyor motor at the time of the accident.

Current at this colliery is generated as three-phase current at 440 volts. It is used at this pressure chiefly for pumping and for driving coal conveyors. Armoured cables are used.

At the gate-end switch, controlling the conveyor motor south of the shaft in the Coking Coal Seam, there was, at the time of the accident, a short length of armoured cable connecting up a 400 volt-100 volt transformer, current at the lower pressure being used for lighting. The deceased was heard to groan when in the act of switching off the gate-end switch, and he was then seen to have his left hand on the lighting transformer. An effort was made to pull him off, but it was not for some few minutes afterwards that he was freed by the switching off of the current at a switch in series with the gate-end switch some 20 or 30 yards away.

An effort was made to restore deceased, but it was unavailing.

Examination of the lighting transformer showed that the cable inside the case had become bared, and there is no doubt that contact between this bared part and tbe transformer case was the primary cause of the accident. In the ordinary way the transformer case would be connected to earth through the armouring of the incoming cables, but this connection (through a brass gland) must have been a very poor one at the best, and it had failed. It is probable that deceased placed his hand on the transformer cable in approaching the gate-end switch, and that in so doing he made contact between the bared cable and the transformer case and caused the armouring, which had been very poorly secured, to slip out of the brass leading-in gland.

In this way the transformer case would be made "live."

Deceased was standing on a wet iron plate at the time of the accident, and it is probably due to this fact that the 240-volt shock he received proved fatal. The neutral point of the generator was connected to earth.

This case indicates the uncertainty of depending upon a gland for an earth connection. It is better not to depend only upon a gland, but to connect in addition a short length of cable to the armouring of the incoming cable and to the body of the transformer by properly designed lug connections. No stress can possibly in these circumstances be taken by the earth connections, and this is as it should be. The earth circuit is frequently regarded as of no great importance, certainly of less importance, than the main circuit. It is not, however, of less but of greater importance, for if the latter fails it merely means the shutting down of the machine, whereas if the former fails it may result in a fatal accident.

The transformer gland was evidently not designed for the purpose for which it was used, namely as an earth connection to the cable armouring. It was probably intended merely as an oil-tight gland for the cable.


Sources
  • 1910 Mines Inspectors Report (Cd 5676), Scotland District (No. 1) by W. Walker, H.M. Inspector of Mines, Page: 21 Where to find this report
  • 1910 Mines Inspectors Report (Cd 5676), Scotland District (No. 1) by W. Walker, H.M. Inspector of Mines, Page: 52, Accident Number: 11 Where to find this report

Researchers

If you are researching John Martin (e.g. for family tree purposes) and you would like to hear from others with the same interest then please complete the details in the following form. We will show the information you provide on this page so that you can be contacted.

What is your name?
What is your contact email address?
What is your research interest?

 

Return Return   Return Return to Top

 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 31 Dec 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print