|
George Bellinghan
By Electricity. Five persons were killed by the same number of accidents due to electric shock. I give below a more detailed description of them than appears in Appendix I, as they suggest means which should be taken to prevent similar accidents in future. I was not in charge of the district when the first four of these accidents occurred, and I, therefore, give below a summary of the reports made by Mr. Nelson, His Majesty's Electrical Inspector of Mines, on them. The third occurred at Blantyre Ferme Colliery, belonging to Messrs. A. & G. Moore & Co., on May 12th.The deceased was a roadsman, and he was actually engaged on the main haulage way in repairing the damage caused by a runaway hutch at the time of the accident. The main haulage way in Blantyre Ferme Pit is level for about ¼ mile from the shaft bottom, but from that point it dips 1 in 7. The roof is supported by side props, with steel girder crowns. The runaway hutch was carrying timber in-bye and was in charge of two men. They seem, however, to have spragged it poorly, with the result that it got out of control at the top of the dip. In running down the incline it displaced some props bringing one of the steel girders down on to the cable. The flange of the girder cut through the insulation of the cable to the copper core, and deceased, in attempting to lift the girder in order to clear the roadway, received a fatal shock. The girder in the position it fell was not touching earth, it fell with one end on the cable and the other on a wooden sleeper, so that it was practically insulated. Current at this colliery is obtained from the Clyde Valley Electric Power Company as three-phase current at 400 volts. The neutral point of the system is connected to earth, and, therefore, deceased would receive a 230-volt shock. The jury found a verdict of "Accidental Death," and they attached no blame. The damaged cable was an unarmoured bitumen insulated cable. There can be no doubt, however, that the conditions are precisely those in which mechanical protection is required for cables ; a roof supported by girders and a fairly steep incline, with the constantly present possibility of a hutch or set of hutches getting out of control. Both the electricians at the pit, and one of the owners, agreed that the use of armoured cable is desirable in such cases. Safety lamps are in use at the pit. An effort was made to restore deceased, but (as usually happens) some minutes elapsed before a start was made.
If you are researching George Bellinghan (e.g. for family tree purposes) and you would like to hear from others with the same interest then please complete the details in the following form. We will show the information you provide on this page so that you can be contacted.
|
|||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 31 Dec 2022
|
Search |
|
|||