G. Perry
The first explosion (No. 27) took place in the South Duffryn Colliery, belonging to the Plymouth Iron Co., on the 27th February, resulting in the loss of two lives; from my inspection in this case it was clear that an air door had been neglected, which left a considerable portion of the district unventilated, and which became filled with inflammable gas. The discipline was so bad that there was considerable doubt as to whether the fireman was or was not justified in taking his "open light to the point where he fired the gas." Doubtless the lamp station was much too near the workings where locked safety lamps were used. Lamp stations should always be placed at a sufficient distance from the workings, and in such a position as that the current of air passing them shall not be prejudicially affected by the opening or closing of doors. I consider this explosion was entirely due to the bad discipline which prevailed at the time.