logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Master Name Index
What's new in the site
Donate to support the Museum
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious

  Individual Details   Individual Details  
 


Samuel Arthur

Age:   11
Died:   11th Nov 1869
Accident:   11th Nov 1869
Year Born:   abt. 1858
Colliery:   Hendreforgan
Company:   Alexander Bain
Occupation:   Collier
Notes:  
Killed by explosion of gas
Buried:   [not known]
Category:  

Description

The seventh explosion occurred in the Hendreforgan Colliery, Swansea Valley, belonging to Mr. Alexander Bain, on the 11th of November, and at the inquest I gave the following evidence:—

Swansea, 18th November, 1869.

Since the explosion I have made two careful inspections of the Hendreforgan Colliery, to ascertain the cause of the explosion there on Thursday, the 11th instant, resulting in the loss of six lives.

The colliery is won by a slope (engine plane) or bully from the surface, falling from 12 to 20 inches per yard, and is about 400 yards long, intersecting some six or seven veins of coal, three of which are now being worked, namely ; the Little Vein, the Big Vein, and the Brass Vein; and the explosion occurred in the last.

The colliery is worked for the most part with open lights, not safety lamps ; and the ventilation is effected by a furnace placed at the bottom of a chimney on the surface.

The total quantity of air passing into the colliery was only 3,600 feet per minute, which passed down to the letter A in one current.

At that point a split of about 1,000 feet per minute went in the direction of B, and underneath the bully to C; the remainder, 2,600 feet, passing on to the bottom of the bully D, where that current was split, a very small portion passing up to E and F, and joining the first split at point B, the other portion passing around the face of the east level workings G and H.

All the splits or currents again joined at I, and then passed on to ventilate the workings in the Big and Little Veins.

In my opinion the quantity of air, only 3,600 feet per minute, was much too small for the proper and safe ventilation of the colliery, and its distribution or application was most defective, so much so that the gas from the old workings, F, was allowed to pass on to the bully at A, where doubtless it came in contact with a naked light, and caused the explosion.

Only a few days before the explosion occurred the ventilation of the colliery had been changed, and the air put to travel the way I have described.

Unfortunately no stopping or ganging had been placed between the bully and the letter B, (i.e.) between the intake and the return air course; the result was that very little air, if any, passed round the old workings E and F, where, no doubt, gas accumulated and passed to A, and where, as already stated, it exploded.

It was doubtless a great blunder on the part of the man in charge of the colliery not to have had a stopping placed at A, which would have prevented the gas issuing on the bully at that point, and in all probability prevented the explosion.

The arrangement of the ventilation was of the worst description ; the same current of air having to pass through the workings in all the three veins, instead of supplying a fresh current of air to each.

In all my experience I have never met with a case where less knowledge of mining was brought to bear, and to that fact I attribute the explosion and loss of life.

I would strongly recommend that the colliery be at once placed under the care of an experienced mining engineer; that the quantity of air be increased to 12,000 or 15,000 feet per minute; and that the workings in each vein of coal be supplied with a current of fresh air.

A verdict of accidental death was returned by the jury, who recommended that my suggestions should be carried out forthwith, and the coroner severely reprimanded the owner, Mr. Alexander Bain, for entrusting the management of his colliery to an incompetent person.


Memorial: 1869 Hendreforgan Colliery Disaster

Memorial Image


Sources
  • 1869 Mines Inspectors Report (C 124), South Wales District by Thomas E. Wales, H.M. Inspector of Mines, Page: 111, Accident Number: 98 Where to find this report
  • 1869 Mines Inspectors Report (C 124), South Wales District by Thomas E. Wales, H.M. Inspector of Mines, Page: 119, Accident Number: 98 Where to find this report

Researchers

If you are researching Samuel Arthur (e.g. for family tree purposes) and you would like to hear from others with the same interest then please complete the details in the following form. We will show the information you provide on this page so that you can be contacted.

What is your name?
What is your contact email address?
What is your research interest?

 

Return Return   Return Return to Top

 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 30 Apr 2023

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print