| Notes: | Explosion of firedamp in the Five Feet Mine. The portion of workings situated beyond a fault apparently became foul, consequent upon the space for air passage at the working faces being too small ; and the ignition was caused by a shot which blew out the stemming. The area of the intake was 50 feet ; but at the faces and crossings the whole of the air had to pass through six iron pipes, each being about 1 foot area, or a total of only 6 feet area, for an average length of 41 yards, which was insufficient for the quantity of gas that was being given off. An escape had been allowed which admitted more air into the workings, but that was stopped on the morning of the explosion. The Jury at the Coroner's Inquest found a verdict of accidental death, with a recommendation that the suggestion of the Inspector of Mines of making double roadways and cut-throughs instead of single drifts and long piping be adopted ; and also that the proprietors be requested to discontinue the use of gunpowder as much as practicable, and that all shots be fired by the fireman only ; Explosion, firedamp, ignition caused by blown-out shot |