An explosion of gas caused by shot-firing occurred at the Wallsend "G" Colliery, Northumberland, (Wallsend and Hebburn Coal Co. Ltd.) on March 18 at 6.30 p.m. in the North East Section of the Middle Curve district in the Yard Seam causing injuries to one person. The seam was worked on the longwall system with gateways about 12 yards apart, the coal being undercut by a compressed air driven coal cutter.
The seam was about 3ft. thick with 8ins. of ramble which came away as the coal was removed. Above the ramble was a hard white sandstone, the lower layers of which fractured at regular intervals usually corresponding with the depth of the cut, but occasionally there was general roof weighting which sometimes broke down the roof at the face. There had been weighting about 24 hours before the accident, the roof having fallen at the face of a working place about 40 yards away from the spot where the shot which caused the ignition was fired.
After the accident, a roof fissure could be traced from the position of the shot to the point where the man was burned. As the workmen in the intervening roads saw no flame it is assumed that it travelled along the fissure or cavity and burst out into the face 40 yards away and then died out in a few yards. Only at this point could signs of burning be seen anywhere in the face.
The injured man's marrow was not burned as he happened to be in a sheltered position. He says he heard the report of the shot followed by a rumbling noise from the right, then a hissing sound, and finally a flash of flame which died out after passing him.
The investigations following this accident showed that the deputy had fired two shots one after the other, the second igniting the gas. The holes were 3ft. 6ins, and 3ft. 3ins. deep, one each side of the canch lip and about 5ft. apart, and were charged with 8 and 6 ounces of Saxonite respectively, fired electrically by a No. 6 high tension detonator placed in the inner end of the outer cartridge in each case. The eight ounce shot did very little work and is said to have sounded very faint. The second shot, according to the deputy, sounded "terribly hard" much louder than was expected with 6 ounces of explosive.
A good deal of doubt existed in this case as to whether the shotholes were properly examined for breaks before being charged as a distinct break was found across the shothole after the accident. The deputy appears to have contravened the Explosives in Coal Mines Order in that a proper examination for inflammable gas within a radius of 20 yards of the shot was not made between the firing of the first and second shots.
Messrs E. H. Frazer and T. A. Rogers who investigated the accident reported:
"We have come to the conclusion that the charge of the second shot was not pushed to the back of the shot hole and that the first cartridge put in was arrested at an open break down which the flame of the explosive travelled and ignited an inflammable mixture in it. The cavity probably could not be seen before firing the shots but we are of opinion it would have been discovered had proper tests been made with a scraper."
Firedamp had not been reported in the district by the deputies for nearly three months prior to the explosion. Gas was found by H.M. Inspectors at three places in the district the day following the accident.
Samples of explosive of the same date of manufacture together with detonators were tested and found to be in order.
Source: 1929 Mines Inspectors Report