Vane Tempest CollieryMiscellaneous Notes and IncidentsVane Tempest Colliery, Durham (Below ground — Shuttle car fire — Safety lamp mine): An American-built shuttle car, after being used at work, was left at the entrance to the underground charging station so that the batteries could be charged. An electrician later commenced driving the car towards the station when he smelt burning rubber and, upon stopping the car, he found the flexible cable to the offside battery on fire. The fire was attacked with sand and stone dust from the adjacent station and extinguished. Eighteen inches of the cable had been destroyed by the fire, and the conductors of the cable had been fused asunder as a result of the short-circuit which developed (Plate II). After the fire the 300 amps. fuses were found to be intact. It is possible that the fault current was limited to a value less than the operating current of the fuses because of the condition of the batteries. There was evidence of the cable having been crushed between part of the battery box and the wheel mudguard, the battery being tilted and its weight being supported by the cable. This was probably the cause of the damage sustained by the cable, and support is given to this opinion by the finding of such a condition in a spare shuttle car standing in the shaft bottom ready to go inbye to commence a shift. Suitable guards were to be fitted by the makers to prevent the battery box from shifting. Source: Report of H.M. Principal Electrical Inspector of Mines for 1949, from a copy held in the Scottish Mining Museum, Newtongrange, Midlothian
|
![]() |
||||||||
|