Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Master Name Index
What's new in the site
Donate to support the Museum
Mining
Mining History
Colliery Index
Colliery Index
List of Mines
Colliery Managers
Abandoned Seams
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious

 Misc. Notes Return to Index Misc. Notes 
/ \

Usworth Colliery

Miscellaneous Notes and Incidents

Usworth Colliery, Durham (Below Ground — Accidental shot firing from a signalling system — Safety lamp mine): On a main haulage roadway undergoing repairs, a deputy, assisted by a stoneman, charged a shot hole in a roof ripping using Penrhyn (sheathed) Explosive which was to be detonated electrically. In preparation for firing the charge he laid the shot firing cable along the floor and disconnected the inbye end of a length of 20 yards of similar cable which had been used to extend the bare wire signalling system in that part of the roadway under repair, coiling it clear of the outbye side of the ripping. Three stonemen were left in the vicinity of the ripping while the deputy walked a few yards outbye with his exploder. Just at that moment a detonation occurred. One of the stonemen was severely injured and died in hospital seven days later. The others escaped injury.

The evidence appears to suggest that the stoneman, in order to assist in the work, had intended to connect the detonator leads to the shot firing cable, but had mistakenly connected them to the signalling system cable extension and the detonation was ignited.

The signalling system was of the intrinsically safe type and, although incapable of igniting firedamp, detonators can be fired quite readily under the circumstances stated. In connection with a non-fatal accident at Fishburn Colliery, Durham, under somewhat similar circumstances, and described in my report for the year 1949, I stressed the necessity for removing discarded shot firing cables to the surface, and the proper extension of the signalling system.

The fatal accident just described, and reference to three non-fatal accidents elsewhere in this report under similar circumstances, again emphasises the necessity for taking adequate precautions against such accidents, which should include the prohibition of the use of shot firing cable for signalling wires.

Source: Report of H.M. Principal Electrical Inspector of Mines for 1950, from a copy held in the Scottish Mining Museum, Newtongrange, Midlothian

Index  index of Miscellaneous Notes and Incidents for Usworth Colliery

Colliery Page  main page for Usworth Colliery

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 31 Dec 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print