Two fillers were overcome by fumes from an underground fire at Sacriston Colliery, Durham. When recovered by a party of rescuers about an hour later, one was in a collapsed condition and the other unconscious. The seam was 1 ft. 6 in. thick and the relevant workings comprised an 80-yard longwall face, on which an electrically driven skip-conveyor was worked, with a mothergate at one end and a tailgate at the other. The mothergate served as the intake airway and the tailgate as the return. There were 13 persons at work in the district when a fire originated at a heap of trailing cable 50 yards from the face of the mothergate. Some 35 yards of cab-tyre sheathed trailing cable were completely burned out; two props used as roof supports and several loose planks were also burned.
Eleven of the persons on the inbye side of the fire withdrew in safety, some through the smoke on the mothergate and others along the tailgate. By means of chemical fire extinguishers, brought from the surface and used by the manager and others, the fire was got sufficiently under control in about an hour to enable the undermanager with a party to travel along the tailgate which was about 200 yards long. One of the fillers was found about half-way to the face and the other ten yards from the face. The filler found nearest the face was unconscious; he was carried into fresh air and oxygen administered to him before he was sent to hospital.
The trailing cable had developed a short circuit at a faulty dry joint and the arc set the rubber on fire before the circuit breaker, which was set unnecessarily high, tripped and cut off the current. Following the accident the circuit breaker overload setting was reduced and the practice of soldering joints in trailing cables instituted. The electrical aspect of such accidents is more fully dealt with in the Annual Report of H.M. Electrical Inspector.
Apart from small supplies of sand and stone dust, there were no means of fire-fighting in the district. Arrangements were afterwards made for the provision in each district of fire extinguishers, larger quantities of sand and stone dust, a small pump and pipe lines and one portable hand pump and water barrel mounted on a bogie. Further reference to fire-fighting appliances and organization is made later in this report.
Source: 1935 Mines Inspectors Report