Ravensworth Ann Colliery
Miscellaneous Notes and Incidents
At Ravensworth "Ann" Colliery, Durham, a shot-hole 4 ft. 6 in. deep in a top canch near the face of a longwall gateway was charged with 24 ounces of Antifrost Gelammonite No. 1 and electrically fired. The shot ignited firedamp. The flame apparently travelled some 15 yards along the face in a roof break, before issuing from a roof cavity, where it slightly burned a stoneman who was building a packwall there. The authorized shot-firer stated that before charging the hole he examined it for breaks but found none. He admitted, however, that he failed, before firing the shot, to make an examination of all contiguous accessible places within a radius of 20 yards from the place where the shot was to be fired — a contravention of Clause 6 (f) (i) of the Explosives in Coal Mines Order. The shot-firer also failed to observe the provisions of Clause 2 (e) of the Order in that before firing the shot he failed to see that the stoneman had taken proper shelter. Disciplinary action was taken against him. The accident illustrates once again the need for rigid compliance with the very common-sense requirements of the Explosives in Coal Mines Order. The risk of an accident of this type initiating a disastrous explosion needs no emphasis.
Source: 1935 Mines Inspectors Report