Linton Colliery
Miscellaneous Notes and Incidents
Underground Fires. — A pliable armoured coal cutter trailing cable on a 500 volt, 3 phase, A.C. earthed neutral system, failed at a badly repaired part of the cable and took fire at Linton Colliery, Northumberland. The gate end switch had overload trips on two phases only and was not tripped by a short circuit between two phases and the subsequent fault between one phase and earth that developed. A new gate-end switch with two overload trips and leakage protection was subsequently installed.
Source: 1929 Mines Inspectors Report