Langley Park CollieryMiscellaneous Notes and IncidentsLangley Park No. 1 Colliery, Durham (Below ground — Safety lamp mine) A stoneman received burns on his hand and face as a result of a flash from a wire-armoured cable which was live when the point of a pneumatic pick penetrated the cable. The system was 625 volts, 3-phase, 50 cycles, A.C., and the neutral point of the system was earthed. The stoneman and his mate were employed enlarging an existing hauler room. Top canch shot firing had been carried out during the preceding weekend, and as a number of large stones had to be broken up they were using a pneumatic pick. There were three armoured cables at the place where they were working and these had been dropped on the floor for a distance of about ten yards. They were partly covered by a 10-inch steel pipe but for a length of about 15 feet the cables were covered by only rubble and planks. About the time of the accident, the stoneman was using the pick to break up a boulder and when he had completed this he handed the appliance over to his mate at the latter's request. in doing so, however, the pick slipped from his grasp and dropped to the floor where, according to the evidence, the point of the pick penetrated the 625 volt, 3-phase, A.C., single wire armoured cable, with resultant arcing or flashing from the cable which caused his burns. The mate, who saw flames persisting around the hole in the cable, ran to the nearby substation and obtained a bucket of sand. On his return to the damaged part of the cable, the flames were out. An electrician who was called to the fire, saw that the 5,000 volt switch controlling the three single-phase step-down transformers, each 100 KVA, had tripped out on earth leakage. The circuit-breaker on the 625 volt side was not fitted with earth leakage protection and the switch did not trip. A core-balance transformer was inserted in the run of 625 volt wire-armoured cable and the secondary winding was designed so as to operate the trip on the 5,000 volt switch on the occurrence of a fault. This accident draws attention to the necessity for adequately protecting cables laid on the floor during stone ripping work. Source: Report of H.M. Principal Electrical Inspector of Mines for 1951, from a copy held in the Scottish Mining Museum, Newtongrange, Midlothian
|
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 31 Dec 2022
|
Search |
|
|||