At Highley Colliery, Salop, on 16th September at 7.30 a.m., two men were burnt, but not seriously, by a small explosion of firedamp in a crut which had been driven to a rise fault. Naked lights were used throughout the seam. A commencement was made to drive up the fault leader to a seam of coal about 7 ft. above. The roof had been taken down at the fault and formed a cavity 13 ft. high from the floor of the crut. The seam was reached and pierced vertically for a distance of about 3 ft. and a mound of dirt about 5 ft. high formed immediately beneath the cavity. The night shift men left the place at 5 a.m., and the night fireman says he inspected it at 5.15 a.m., and found it free from firedamp. At about 7.15 a.m., the two injured men were about to commence work and one of them got on the top of the mound of dirt and raised his candle up level with his head to examine the coal seam, and, in so doing, ignited firedamp in the cavity. His mate was at the foot of the mound. Flame came out of the hole and into the crut and quickly died out, but both men were slightly burned thereby. Coal dust played no part in the explosion ; the combustible content of the dust in the place varied from 23.9 per cent. to 41 per cent. Apparently a small amount of gas accumulated in the cavity during the quiet period between shifts, and was quickly dispersed when the air was disturbed by working operations. The face of the crut was a short distance in advance of the ventilating current and steps had not been taken to carry the air current into the place although air pipes had been provided for this purpose.
The mine has been worked for about forty years and gas has never been seen in the district before, and naked lights have always been used. Since this occurrence the use of naked lights has been discontinued and safety lamps put into use throughout the mine.
Source: 1924 Mines Inspectors Report, Midland and Southern Division (No. 8) by H. A. Abbott, H.M. Inspector of Mines [DMM Ref: L-01624 - Tom Bainbridge Collection]