Hazlerigg CollieryMiscellaneous Notes and IncidentsHazlerigg Colliery, Northumberland (Below ground — Safety lamp mine) An assistant electrician, aged 31, had repaired a gate-end box and before closing the front access cover he received an electric shock and burns from the live parts when demonstrating to the 18-year old apprentice electrician, who accompanied him, how the contactor switch operated. The power supply was 625 volts, 3-phase, 50 cycles, A.C., and the neutral point of the system was earthed. On the morning of the accident, the electrician was instructed to take the apprentice inbye to find a fault in a coal-cutter gate-end box which had been giving trouble. When he arrived at the gate-end box, he found that the coalcutter men had opened the isolator. He withdrew the plug at the gate-end box, made a conductor test which showed that there was a high resistance at the contacts of the local control stop-start switch on the back of the front access cover, and replaced the contacts. The electrician was about to close the access cover but remarked to the apprentice that he would demonstrate how the contactor operated. To do so, he placed the pilot link in the "LOCAL" position and then proceeded to close the isolator to supply power to the contactor. On this type of gate-end switch, the isolator is operated by the isolator handle attached to the access cover engaging in a dog clutch on the isolator spindle, and the access cover cannot be opened unless the isolator is in the "OFF" position. With the access cover open, however, the electrician used a spanner to engage in the dog clutch in an attempt to close the isolator. He had apparently closed the isolator using both hands but the spanner slipped and the back of his left hand came into contact with the live parts of the fuses for the potential transformer which had been made live. The electrician received severe burns to the back of his left hand and an electric shock. The apprentice tried to pull him away from contact with the switch and was eventually successful, receiving a slight shock in doing so. The electrician was not unconscious and after treatment at the pit he was removed to hospital where he was detained for observation. He had not started work after fourteen days. There is no doubt that the electrician owes his life to the prompt action of the apprentice who persisted in trying to drag him clear even though he was receiving electric shocks in the process. Great care should be exercised at all times by electricians in charge of apprentices and it is to be regretted that an electrician, who ought to know better, should deliberately demonstrate bad practices. Source: Report of H.M. Principal Electrical Inspector of Mines for 1951, from a copy held in the Scottish Mining Museum, Newtongrange, Midlothian
|
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 31 Dec 2022
|
Search |
|
|||