Hazlerigg CollieryMiscellaneous Notes and IncidentsHazelrigg Colliery, Northumberland (Surface) : The electrician-in-charge had supervised the installation of a bank of new 2,750 volts switches in the engine house at the surface of the mine, and after insulation tests had been made he went to the main substation about 300 yards away to close the switch controlling the cable to the new board. In attempting to do so, hot oil and vapour was ejected from holes in the hood of the switch and he received slight burns to his hand. The switch tripped out under heavy load immediately. After the old type switches had been disconnected and removed, the new switches were moved into position. In connecting the incoming cable to the new board it was found there was little slack, but the conductors were attached without difficulty to the top and middle busbars. The conductor for connecting to the bottom busbars had to be cut, but in doing so the electrician cut off too much. It was found necessary to make a copper extension plate to be inserted between the busbar and the cable conductor, and this work was carried out, the connections being insulated with tape. The trifurcating cover was replaced and the box filled with cold filling compound, and insulation test results with a 500 volts "Megger" appeared to suggest that the work was satisfactory. When the attempt was made to close the feeder switch, however, an electrician standing near the trifurcating box just completed heard a faint hissing sound for a second or two from the box. An examination of the trifurcating box showed that the bottom left hand corner of the extension plate had been fused away for about one inch by inch and there was considerable fusion on the casing of the box. There was evidence to show that possibly the extension plate had been forced against the casing of the box and the tape punctured when the cover was bolted into position. An examination of the feeder switch in the main substation showed that there was considerable fusion on the contacts of one phase of the switch as if a heavy fault current had been interrupted on this particular phase. There was no excessive fusion on the contacts of the two other phases. The system was 2,750 volts, 3-phase, 50 cycles, A.C., and the neutral point of the system was earthed. Leakage protection was not fitted to any of the circuit breakers on the system. It is well known that a 500 volts insulation test is seldom satisfactory for testing a 3,000 volts cable and apparatus installation. This was appreciated following the accident and a testing instrument suitable for the purpose was to be obtained. Source: Report of H.M. Principal Electrical Inspector of Mines for 1950, from a copy held in the Scottish Mining Museum, Newtongrange, Midlothian
|
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 31 Dec 2022
|
Search |
|
|||