At Wardley Shaft, Follonsby Colliery, Northumberland, electricians had been setting up the rotor bearings and the engineman was making trial runs with the cages. On the third journey the East cage was descending and had reached a point about 9 fathoms from the bottom when the engineman "felt he had lost his weight," but he did not notice any jerk. The engineman was braking in the usual way at the time. The examination of the shaft showed no defects and the cage shoes were in order. The cage was very slightly damaged. The cause of the breakage would appear to have been corrosion. The shaft is used to lower and raise pumpmen and the cages stand practically throughout the day in the same position in the shaft, either 20 fathoms above or below meetings. A sector on the West side of the shaft is bratticed down to the Maudlin Seam, about 1,080 feet, and cold intake air behind the brattice causes condensation in the shaft for a depth of about 120 feet below the surface. The portion of rope standing in this saturated atmosphere was corroded.
Source: 1927 Mines Inspectors Report